Applications:
Graphitization treatment of carbon materials, synthetic graphite film (Polyimide graphite flake and abbreviated PI film), heat conductive materials, carbon fiber rope, carbon fiber, C/C composites, Graphene, battery anode materials, VGCF purification and de-ironing process of Carbon Nanotube (CNT), sintering of advanced ceramics and other materials which can be sintered in graphite hot zone (carbon included environment).
CX-GF series are vertical top and loading batch type induction heating furnaces, excellent temp uniformity which is ideal for powder type materials. Max working temp to 3000C can meet carbon materials graphitization treatment.
Artificial graphite is a widely used anode material for new energy batteries and energy storage. It is made from petroleum coke, needle coke, etc., through carbonization, graphitization and other processes. With our high temp graphitization furnace, the carbon content can be improved to more than 99.95%,even to 99.99995%, and the degree of graphitization will be improved to 99% or more.
Application:
Graphitization treatment of carbon materials, synthetic graphite film (Polyimide graphite flake and abbreviated PI film), heat conductive materials, carbon fiber rope, carbon fiber, C/C composites, Graphene, battery anode materials, VGCF purification and de-ironing process of Carbon Nanotube (CNT), sintering of advanced ceramics and other materials which can be sintered in graphite hot zone (carbon included environment).
Features:
Optionals:
Chiller
Gas purifier
Graphite container
Temp measure below 1000C
Parameters:
Model | CX-GF20/30VT | CX-GF30/50VT | CX-GF40/AM | CX-GF50/AM | CX-GF60/AM |
Max Design Temperature | 3000C | ||||
Work Temperature | 2900C | ||||
Temperature Uniformity | ±10C (ΔT between 1000C and 1600C) | ||||
Work zone size (mm) | Φ200×300 | Φ300×500 | Φ400×1000 | Φ500×1000 | Φ600×1600 |
Max. Loading Capacity | 9L(Lab) | 35L(Lab) | 125L | 196L | 452L |
Rated Power | 80 KW | 120 KW | 150 KW | 200 KW | 300 KW |
Frequency | 2000 Hz | 2000 Hz | 2000 Hz | 1500 Hz | 1500 Hz |
Vacuum (CEDRT)* | Can be customized | ||||
Working Atmosphere | Vacuum / Inert Gas (Ar) Vacuum is only permitted below 2200C | ||||
Supply Voltage | 3P, 380V, 400V, 415V, 480V can be customized | ||||
Cooling Water Pressure | 1.5-2.5bar |