Biomass Carbonization Furnace for High-Temperature Processing

1700°C Biomass Carbonization Furnace for High-Temperature Processing

Vacuum or controlled-atmosphere thermal processing that converts organic materials into carbon-rich substances for the artificial graphite industry.

1700°C biomass carbonization furnace for high-temperature processing

Vacuum Pyrolysis to High-Performance Carbon

The CXinduction™ 1700°C high-temperature carbonization furnace converts polymers (PAN, phenolic resin) and biomass into high-performance carbon materials under vacuum or controlled atmosphere. After high-temperature treatment, biomass carbon is widely used in battery anodes (lithium/sodium-ion), conductive additives, adsorption materials and composite reinforcements.

Need a solution for your project?

Applications of Biomass-Derived Carbon

Battery anodes (lithium/sodium-ion batteries).
Conductive additives.
Adsorption materials.
Composite reinforcements.

Material Conversion Routes

Biomass Graphite
Phenolic Resin Hard carbon
Polyimide Artificial thermally conductive graphite
PAN Fiber Carbon fiber
Polycarbosilane Silicon carbide ceramic fiber

Key Features & Parameters

Max Temperature 1700°C
Atmosphere Vacuum / inert gas (N₂, Ar)
Uniform Heating Multi-hot-zone design ensures consistent thermal distribution.
High Purity Low contamination for premium carbon yields.
Automated Control Precision temperature programming.
Tar Treatment Efficient tar disposal system for eco-friendly collection and harmless processing of pyrolysis by-products.

Models and Work Zones

CX-CF40/BM 75 kW; usable space 400 × 400 × 1200 mm; 192 L.
CX-CF50/BM 90 kW; usable space 500 × 500 × 1500 mm; 375 L.
CX-CF60/BM 120 kW; usable space 600 × 600 × 1800 mm; 648 L.
CX-CF60/BM (2000) 160 kW; usable space 600 × 600 × 2000 mm; 720 L.

Technical Parameters

Heating Method Graphite resistance
Control Method Auto & MAN
Temperature Uniformity ±10°C (ΔT between 1000°C and 2200°C)
Heating Rate 15°C/min
Ultimate Vacuum 1.2×10⁻³ mbar; optional high vacuum 5×10⁻⁵ mbar; pressure rise 1.33×10⁻² mbar/hr
Working Atmosphere Fine vacuum (optional) / vacuum / inert gas (Ar or N₂)
Supply Voltage Can be customized
Cooling Water Pressure 2 bar; temperature ≤28°C

Optionals

Water chiller; fine vacuum. Post-carbonization materials can be further enhanced in a graphitization furnace to improve conductivity.